Nikon TE2000U Dual mode / Time lapse / Ratio Imaging Microscope
Fluorescence Filter Settings for the DG-4
|
|
REQUIRES |
|||
SimplePCI |
Light at the specimen |
Dichroic filtercube position on the Microscope |
AND |
DG-4 Filter... |
…in DG-4 position # |
Default Idle Position |
No light |
Any |
|
n/a |
n/a |
WHITE LIGHT |
White Light to filtercube turret **For single-channel filtercubes ONLY** |
UV (DAPI) |
|
"Open" |
|
or |
|||||
B (FITC, GFP, AlexaFluor 488) |
|||||
or | |||||
G (Texas Red, Rhodamine) | |||||
or |
|||||
R (Cy5, AlexaFluor 647 or 633) |
|||||
DAPI |
UV light for excitation of DAPI |
M* (multiple excitation) |
|
DAPI |
4 |
or |
|||||
UV (DAPI) |
|||||
FITC |
Excitation for green-emitting fluorophores |
M* (multiple excitation) |
|
FITC |
3 |
or |
|||||
B (FITC) |
|||||
Texas Red |
Excitation for red-emitting fluorophores |
M* (multiple excitation) |
|
TX RD |
2 |
or |
|||||
G (Texas Red, Rhodamine) |
|||||
380nm |
FURA 380nm excitation |
F-2 |
|
380nm |
2 (3^) |
340nm |
FURA 340 excitation |
F-2 |
|
340nm |
1 (4^) |
manDAPI |
White Light to filtercube turret |
UV (DAPI) |
"Open" |
1 |
|
manFITC |
White Light to filtercube turret |
B (FITC) |
"Open" |
1 |
|
manRhod |
White Light to filtercube turret |
G (Texas Red, Rhodamine) |
"Open" |
1 |
|
man647 |
White Light to filtercube turret |
R** (far-red emission: Cy5, Alexa 647) |
"Open" |
1 |
|
CFP/YFP | 430/500 | M* (86002V2 C & YFP) | 430/25 & 500/20 | 3 / 4 | |
PRIM 470/20 |
Excitation at 470nm for PRIM |
Not currently installed. See Facility Management. |
|
PRIM 470/20 |
4 |
PRIM 410/40 |
Excitation at 410nm for PRIM |
Not currently installed. See Facility Management. |
|
PRIM 410/40 |
3 |
Transmtd (Uniblitz) |
Shutter for transmitted light |
When Transmitted light only: "T" dichroic position. Also see "Setting up for transmitted light imaging" for configuration of transmitted light path. With Fluorescence: Set filters for corresponding fluorescence imaging. |
* The dichroic cube in the M position may need changing. Alternate cubes are stored in the plastic drawer. Move carousel 2 positions counter clockwise from the M position and carefully pull out the dichroic from the left side access port. Please store removed cube in one of the plastic storage cubes.
^ These are the old positions and may be what are programmed in your profile. Imaging is superior with the new settings.
** The filtercube for far-red flruoescence may not be installed in the dichroic turret.
![]() |
![]() |